Halocarbon Refrigerants Detector-Transmitter E2638-HFC

VSKU: 1014000029

    This combination does not exist.

    Contact Us

    Halocarbon Refrigerants Detector-Transmitter E2638-HFC
    Detected gases R12, R123, R125, R134a, R143, R22,
    R404a, R407c, R410a, HFOs, etc
    Default calibration R404a
    Sensor type Metal-oxide semiconductor
    Sampling method Diffusion
    Typical detection range 0...1000 ppm
    Resolution / digital unit 1 ppm
    Response time T90 ca. 60 s
    Sensor lifetime > 5 years
    Calibration interval 12 months
    Signal update Every 1 second
    Self-diagnostics Full functionality check at start-up
    Warm-up time ≤ 1 min
    Power supply 11...30 VDC / 24 VAC
    Power consumption < 2 VA
    Digital interface RS485, Modbus RTU protocol
    Analog outputs 2 × 4-20 mA / 0-10 V, user settable